Manufacturer Company

- Descriptions
- Brochures
- Videos
General Definitions
- Tunnel Dimension: 500 mm (Width) 300 mm (Height)
- Conveyor (Belt) Band Speed: 0.22m / sec
- Conveyor (Carrier) Maximum Load: 170kg
- Dose Per Exam: <2.9μGy / hour
- Resolution: < 0.101mm
- Penetration: 14 mm Steel
- Film Safety: Guaranteed ISO1600 Film
- X-ray Leakage: <0,05 μGy
X-ray Generator
- Direct Production: Up
- Angle Production: 80 degrees
- Anode Voltage: 80KV
- Anode Power: 0,4mA
- Cooling / Work time (duty cycle): Oil Cooling / 100%
Display System
- X-ray Sensor: L-shaped photodiode array (mono energized), 12bit depth
- Monitor: High resolution color, LCD compatible, 19inch
- Image Processing: Edge enhancement, image enhancement, image lighting, reduction of darkening, image reversion, image rewind.
- Image Grayness Level: 4096
- Image Maximum Resolution: 1024 1280 pixels.
- Image Processing: 24bit real time processing.
- Image Storage: 200,000 images in real time.
- Zone & Zoom: 1-9 image zones , enlargement of 2, 4, 8, 16 times. full screen continuous observation.
Installation Data
- Working Temperature / Humidity: 0 ℃ - 45 ℃ / 20 - 95% (non-condensing)
- Storage Temperature / Humidity: -20 ℃ - 60 ℃ / 20 ~ 95% (non-condensing)
- Operating Power: 220VAC (± 10%) 50 ± 3Hz
- Power Consumption: 1.0 KW (max), 0.3KW (working)
- Noise: db. <65